6. Security System Management
1. Work principle of the access control system:
ZKAccess5.0 Security System is a WEB-based management system, providing normal access control functions, management
of networked access control panel via computer, and unified personnel access management.
The access control system can set the opening levels of registered users, namely, allowing some personnel to open some
doors by verification during a time period.
Otherwise, the system supports the use of data from the access control panel for attendance purpose, to save the device
resource.
It facilitates the management and support of multiple databases, including MySQL, SQL Server, and Oracle. Designed based
on multi-business convergence, it supports service extension, such as attendance, patrol, visitor management, etc., and
supports multiple languages.
2. Access control system parameters:
256 time zones;
256 access levels;
Three holiday types and 96 holidays total;
Anti-pass Back function;
Interlock function;
Linkage function;
First-Card Normal Open function;
Multi-Card Opening function;
Remote door opening and closing;
Real-time monitoring via Web browser;
3. Operation functions of access control system:
Click to enter the [Access Control System] and the main interface is [Real-time Monitoring].
Access Control System Management primarily includes Access Control Time Zones, Access Control Holiday, Door Settings,
Access Levels, Personnel Access Levels, Real-time Monitoring, Reports, etc.
6.1 Access Control Time Zones
Access Control Time Zone can be used for door timing. The reader can be made usable during valid time periods of certain
doors and unusable during other time periods. Time Zone can also be used to set Normal Open time periods for doors or set
access control levels so that specified users can only access specified doors during specified time periods (including access
levels and First-Card Normal Open settings).
The system controls access according to Access Control Time Zones. The system can define up to 255 time zones. During a
week, you can define up to three intervals for each day and three holiday types for each time zone. Each interval is the valid
interval in the 24 hours of each day. The format of each interval for a time zone is: HH: MM-HH: MM, this is accurate to
minutes in the 24-hour system.
Initially, by default the system has access control time zone named [Accessible 24 hours]. This time period can be modified but
cannot be deleted. The user can add Access Control Time Zones that can be modified.
1. Add Access Control Time Zone:
(1) Click [Access Control System] - [Time zones] - [Add] to access the Time Zone setting interface;