201 Circle Drive N, Suite 116 Piscataway, NJ 08854 Tel: 732-412-6007 Fax: 732-412-6008
www.zkaccess.com
1. Click [Access Control System] - [Door Configurations] - [Linkage Setting] - [Add] to show the Linkage setting interface;
2. Enter a Linkage Setting Name (input Linkage Setting Name before selecting the device). After selecting the device the
corresponding Linkage Setting will appear (The system will first determine whether or not the device is successfully connected
and has read extended device parameters such as auxiliary input quantity, auxiliary output quantity, door quantity and reader
quantity. If the system has no available extended device parameters, it will remind the user of failing to set anti-pass back.
Otherwise, it will show Linkage Setting options according to the currently selected device, such as the door quantity, auxiliary
input and output quantity):
The fields are as follows:
Trigger Condition: Please refer to 6.6 Real-time Monitoring for the Real Time Events Description. Except Linkage Event
Triggered, Cancel Alarm, Open Auxiliary Output, Close Auxiliary Output, and Device Start, all events could be trigger
condition.
Input Point Address: Any, Door 1, Door 2, Door 3, Door 4, Auxiliary Input 1, Auxiliary Input 2, Auxiliary Input 3, Auxiliary Input
4, Auxiliary Input 9, Auxiliary Input 10, Auxiliary Input 11, Auxiliary Input 12 (for the specific input point please refer to specific
device parameters);
Output Point Address: Lock 1, Lock 2, Lock 3, Lock 4, Auxiliary Output 1, Auxiliary Output 2, Auxiliary Output 3, Auxiliary
Output 4, Auxiliary Output 6, Auxiliary Output 8, Auxiliary Output 9, Auxiliary Output 10 (the specific output point please refer to
specific device parameters);
Action Type: Close, Open, Normal Open. By default it is closed. To open, the delay time must be set or Normal Close can be
selected;
Delay: Ranges from 1-254 seconds (This item is valid when the action type is Open)
Network Video Recorder: Select the network video recorder;
Bound Channel: Select the bound channel, channel 1-8 is optional.
Note: The Network Video Recorder function is only available for professional version 5.0.8 and above. If you need to use
the Network Video Recorder, please contact our commercial representative or sales support.
3. After editing, click [OK] to save and quit and the added linkage setting will be shown in the linkage setting list.
For example: If you select “Normal Punching Card Open” as the trigger condition, and the input point is Door 1, the output
point is Lock 1, the action type is Open, and the delay is 60 seconds, then when “Normal Punching Card Open” occurs at Door
1, the linkage action of “Open” will occur at Lock 1, and door will be open for 60 seconds.
Note: When editing, you cannot modify the device but can modify Linkage Setting name and configuration. When
deleting a device, its Linkage Setting Record will be deleted, if it exists.
If the system has setting that the input point is a specific door or auxiliary input point under a trigger condition of a device, it will
not allow the user to add (or edit) a Linkage Setting Record where the device and trigger condition are the same but the input
point is ‘Any’.
Conversely, if the device and trigger condition are the same, and the system has a Linkage Setting Record where the trigger
point is ‘Any’, the system will not permit the user to add (or edit) a Linkage Setting Record where the input point is a specific
door or auxiliary input.